[{"data":1,"prerenderedAt":99},["ShallowReactive",2],{"article:aplicacao-do-metodo-por-digitalizacao-3d-para-obtencao-de-medidas-antropometricas-no-modelo-humano-d":3},{"success":4,"article":5,"request":96},true,{"parent":6,"langs":7,"_id":10,"contributors":11,"typeData":28,"data":85,"slugs":94,"slug":95},"f1f23d35-203a-4494-b7cd-e41787bada40",[8,9],"primary","secondary","c278a113-ef8f-407f-a416-eb8a51159108",[12,16,20,24],{"lastName":13,"name":14,"_id":15},"Brendler","Clariana Fischer","c5456388-de16-4524-8e6b-2f9e57417761",{"lastName":17,"name":18,"_id":19},"Teixeira","Fábio","7ab7a6f5-1e25-4b20-9d72-d440a5bf5aa3",{"lastName":21,"name":22,"_id":23},"Zubaran","Gabriela","16dde5a8-07c7-4468-9cb5-f5fd3a9be2cf",{"lastName":25,"name":26,"_id":27},"Mello","Guilherme","f405f543-64ab-4bec-bd77-fb4774cc4ce4",{"startPage":29,"references":30,"endPage":82,"track":83,"has_file":4,"doi":84},4904,[31,34,37,40,43,46,49,52,55,58,61,64,67,70,73,76,79],{"id":32,"label":33},"64b9fe0c-935d-4975-859f-987de2518071","\u003Cp>BLANCHONETTE, P. Jack Human Modelling Tool: A Review. Tech. Rep. DSTO-TR-2364, Defense Science and Technology Organization Victoria (Australia) Air Operations Division, Fishermans Bend, Victoria, Australia, 2010, document ADA 518132.\u003C/p>",{"id":35,"label":36},"433a0a0e-e4e0-4f04-9da2-6cebef42eac0","\u003Cp>BRENDLER, Clariana Fischer. \u003Cstrong>Modelo Humano Digital Paramétrico para análise ergonômica virtual no projeto de produto\u003C/strong>. 2017, p. 335. Tese de doutorado, Universidade Federal do Rio Grande do Sul, Escola de Engenharia, Programa de Pós-graduação em Design, Porto Alegre, RS.\u003C/p>",{"id":38,"label":39},"c9652f1e-75f3-4eff-b904-0de324a902c1","\u003Cp>BRENDLER, Clariana; TEIXEIRA, F. G. Método para Obtenção de Medidas Antropométricas Utilizando um Digitalizador 3D de Baixo Custo. \u003Cstrong>Revista Design & Tecnologia\u003C/strong>, v. 11, p. 53-67, 2016.\u003C/p>",{"id":41,"label":42},"41a2f3f5-1896-4ced-a240-c4ee8781d353","\u003Cp>BRENDLER, C. Método para levantamento de parâmetros antropométricos utilizando um digitalizador 3D de baixo custo. UFRGS, Porto Alegre, 2013, p.148. (Dissertação de Mestrado em Design– PgDesign da Universidade Federal do Rio Grande do Sul).\u003C/p>",{"id":44,"label":45},"37b9d9ff-fab3-4531-88b2-5aceb1d1f1e7","\u003Cp>D'APUZZO, N. Recent Advances in 3D Full Body scanning with applications to fashion and apparel. In: \u003Cstrong>Optical 3-d measurement techniques\u003C/strong>, 9., 2009.\u003C/p>",{"id":47,"label":48},"afcb8107-d347-4f7e-95d3-a8330cfe3045","\u003Cp>HOBSON, D.; MOLENBROEK, J. Anthropometry and design for the disabled: Experiences with seating design for the cerebral palsy population. \u003Cstrong>Applied Ergonomics\u003C/strong>, v. 21, n.1, p. 43-54, 1990.\u003C/p>",{"id":50,"label":51},"8356e9d2-9912-48fa-8cb2-7d627860d63d","\u003Cp>IIDA, I. \u003Cstrong>Ergonomia: projeto e produção\u003C/strong>. 2. ed. São Paulo: Edgard Blucher, 2005.\u003C/p>",{"id":53,"label":54},"009bfed6-9df9-4b61-a4a1-d7d851014398","\u003Cp>JONES, P.; RIOUX, M. Three-dimensional surface anthropometry: applications to the human body. \u003Cstrong>Optics and Lasers in Engineering\u003C/strong>, v. 28, n. 2, p. 89-117, 1997.\u003C/p>",{"id":56,"label":57},"0cb83b89-5f0c-44d2-b565-c7d24abe4510","\u003Cp>KOO B.-Y., PARK E.-J., CHOI D.-K., KIM J. J, CHOI M.-H. Example-based statistical framework for parametric modeling of human body shapes. \u003Cstrong>Computers in Industry\u003C/strong>, v. 73, p. 23–38, 2015.\u003C/p>",{"id":59,"label":60},"62c9db78-2fd4-452b-adba-66638e36634b","\u003Cp>LU, J.; WANG, M. J. Automated anthropometric data collection using 3D whole body scanners. \u003Cstrong>Expert Systems with Applications\u003C/strong>, v. 35, n. 1-2, p. 407–414, 2008.\u003C/p>",{"id":62,"label":63},"114ea09e-9c35-42b9-a1c3-afc33b337136","\u003Cp>LUXIMON, Y.; BALL, R.; JUSTICE, L. The 3D Chinese head and face modeling. \u003Cstrong>Computer-Aided Design\u003C/strong>, v. 44, p. 40–47, 2012.\u003C/p>",{"id":65,"label":66},"291864f2-7686-406a-ba54-3ac1a01c5d13","\u003Cp>NORTON, K; OLDS, T. \u003Cstrong>Antropométrica: um livro sobre medidas corporais para o esporte e cursos da área da saúde\u003C/strong>. Porto Alegre: Artmed, 2005.\u003C/p>",{"id":68,"label":69},"924b8257-3577-465d-90dd-c0f3862c8cdb","\u003Cp>SANTOS, V.; ZAMBERLAN, M. C.; PAVARD, B. \u003Cstrong>Confiabilidade Humana e Projeto Ergonômico de Centros de Controle de Processos de Alto Risco\u003C/strong>. Rio de Janeiro: Synergia, 2009.\u003C/p>",{"id":71,"label":72},"8755c4c8-e7df-4f64-baf7-01f6eec0447c","\u003Cp>SIMMONS, Karla Peavy. \u003Cstrong>Body measurement techniques: a comparison of three-dimensional body scanning and physical anthropometric methods\u003C/strong>. Raleigh: NCSU, 2001. (Tese de Doutorado. North Carolina State University).\u003C/p>",{"id":74,"label":75},"0978af12-389f-4229-b31c-f10696a09827","\u003Cp>TOMKINSON, G.; SHAW, L. Quantification of the postural and technical errors in asymptomatic adults using direct 3D whole body scan measurements of standing posture. \u003Cstrong>Gait & Posture\u003C/strong>, v. 3, p. 172–177, 2013.\u003C/p>",{"id":77,"label":78},"b977b819-1190-4390-9514-c479ffa80576","\u003Cp>TONG, J; ZHOU, J; LIU, L; PAN, Z; YAN, H. Scanning 3d full human bodies using kinects. \u003Cstrong>IEEE Transactions on Visualization and Computer Graphics\u003C/strong>, v. 18, n. 4, p. 643-650, 2012.\u003C/p>",{"id":80,"label":81},"b6c6c85b-4356-45b5-abb9-1c7ab9b7b880","\u003Cp>VEZZETTI, E; MARCOLIN, F. 3D human face description: landmarks measures and geometrical features. \u003Cstrong>Image and Vision Computing\u003C/strong>, v. 30, n. 10, p. 698-712, 2012.\u003C/p>",4918,"gddaigk4","10.5151/ped2018-6",{"primary":86,"secondary":90},{"keywords":87,"excerpt":88,"title":89},"\u003Cp>Digitalização 3D de baixo custo, Antropometria, Análise Ergonômica, MHD\u003C/p>","O objetivo deste trabalho é apresentar uma aplicação do método de obtenção de parâmetros antropométricos estáticos por meio de um digitalizador 3D de baixo custo (BRENDLER, 2013) e descrever as implicações e contribuições ocorridas neste processo. Os parâmetros antropométricos são obtidos e inseridos num modelo humano digital (MHD) para comparação e análise dos resultados em relação às medidas do modelo 3D obtidas pela digitalização. Foram utilizados dois participantes, um do sexo feminino e um do masculino, representando o percentil estatura 5% e 95% respectivamente. Os modelos 3D dos participantes foram adquiridos com uso do dispositivo Kinect da Microsoft. Os resultados obtidos foram extremamente compatíveis o que demonstra a viabilização do método utilizando a digitalização para obtenção de medidas antropométricas para aplicação no MHD. Otimizando o processo de medição, reduzindo o tempo necessário de mensuração com o usuário e aumentando a precisão das medidas antropométricas para auxiliar nas análises ergonômicas do produto.","Aplicação do Método por Digitalização 3d para Obtenção de Medidas Antropométricas no Modelo Humano Digital",{"keywords":91,"excerpt":92,"title":93},"","The objective of this work is to present an application of the method of obtaining static anthropometric parameters by means of a low-cost 3D scanner (BRENDLER, 2013) and to describe the implications","Application of the 3d Scanning Method to Obtain Anthropometric Measurements in the Digital Human Model",[95],"aplicacao-do-metodo-por-digitalizacao-3d-para-obtencao-de-medidas-antropometricas-no-modelo-humano-d",{"target":97,"query":98},"articles/get",{"slug":95},1780315947723]